Air Conditioning System (for Manual Air Conditioning System)
AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Manual Air Conditioning System): TERMINALS OF ECU
TERMINALS OF ECU
1. CHECK AIR CONDITIONING AMPLIFIER
(a) Measure the voltage of the connectors.
HINT: Check from the rear of the connector while it is connected to the air conditioning amplifier.
(b) Using an oscilloscope, check waveform 1.
(c) Using an oscilloscope, check waveform 2.
HINT: When the blower level is increased, the duty ratio changes accordingly.
(d) Using an oscilloscope, check waveform 3.
HINT: The waveform varies depending on the CAN communication signal.
(e) Using an oscilloscope, check waveform 4.
HINT: The waveform varies depending on the CAN communication signal.
(f) Using an oscilloscope, check waveform 5.
HINT: The waveform varies depending on the CAN communication signal.
*1: w/ PTC Heater
2. CHECK FRONT AIR CONDITIONING CONTROL
(a) Measure the voltage of the connectors.