Air Conditioning System (for Manual Air Conditioning System)
AIR CONDITIONING: AIR CONDITIONING SYSTEM (for Manual Air Conditioning System): B1443/43: Air Outlet Damper Control Servo Motor Circuit
B1443/43 - Air Outlet Damper Control Servo Motor Circuit
DESCRIPTION
The damper servo sends pulse signals to indicate the damper position to the air conditioning amplifier. The air conditioning amplifier activates the motor (normal or reverse) based on these signals to move the mode damper to the appropriate position, which controls the air outlet modes.
HINT
Confirm that there are no mechanical problems because this DTC can be set if either a damper link or damper is mechanically locked.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect Techstream to the DLC3.
(b) Turn the ignition switch on (IG) and turn Techstream main switch on.
(c) Select the items below in the Data List, and read the value displayed on Techstream.
Data List / Air Conditioner
OK:
The display is as specified in the normal condition column.
Result:
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Air Conditioning System (for Manual Air Conditioning System)
C -- REPLACE AIR CONDITIONING AMPLIFIER Removal
A -- Continue to next step.
2. REPLACE AIR OUTLET CONTROL SERVO MOTOR
(a) Replace air outlet control servo motor Removal.
NEXT -- Continue to next step.
3. CHECK DTC OUTPUT
(a) Clear the DTC Air Conditioning System (for Manual Air Conditioning System).
(b) Check for DTC Air Conditioning System (for Manual Air Conditioning System).
OK:
DTC B1443/43 is not output.
NG -- REPAIR OR REPLACE AIR CONDITIONING HARNESS
OK -- END