Operation CHARM: Car repair manuals for everyone.

Reading




Read Measuring Value Block (Function 08)

- Connect VAG 1551 Scan Tool (ST) and enter address word -02- for "Transmission Electronics". Advance VAG 1551 Scan Tool (ST) program until "Select function XX" is indicated on display. Scan Tool Connecting and Initial Checks

Indicated on display:


Rapid data transfer HELP
Select function XX



- Press keys -0- and -8-. (To select function 08 "Reading measured value block".)

Indicated on display:


Rapid data transfer Q
08 - Reading measured value block



- Press -Q- key to confirm entry.

Indicated on display:


Reading measured value block
Enter display group number XX



List of selectable display group numbers


Display Group 01 - 05:






Indicated on display:


Reading measured value block 1 ->
1 2 3 4



(Specification) Measured Value Blocks Test Table

- There are always 4 display fields in the measured value block (displayed in physical units, if necessary.)


NOTE:
- Explanation of values in the individual display fields. Measured Value Blocks Test Table
- If the printer is turned ON, the current display is printed out on the log.
- If the specified values of the Throttle Position (TP) Sensor are not reached in display field -2-, the system should first be restored to the basic setting. Basic Setting (Function 04)
- If the values in all display fields are as specified:
- Press -> key.

Indicated on display:


Rapid data transfer HELP
Select function XX