Reading
Read Measuring Value Block
Tools
Special tools, testers and auxiliary items required
- Fault read out device V.A.G 1551 with Diagnostic cable V.A.G 1551/3
Work procedure
- Fault read out device V.A.G 1551, connecting.
- Initiate On Board Diagnostic (OBD). On Board Diagnostic (OBD) For Radio-Frequency Remote Control For Central Locking, Initiating
Measuring value block is divided into 3 display group numbers. Assignment of individual display fields can be found in display group overview starting on page. Evaluating Measured Value Blocks
Indicated on display:
Rapid data transfer HELP
Select function XX
- Press buttons - 0 - and - 8 - to initiate "Read measuring value block", function 08.
Indicated on display:
Rapid data transfer Q
08 Read measuring value block
- Press Q button to confirm input.
Indicated on display:
Read measuring value block HELP
Enter display group number XX
Display group number 001 is used as an example to indicate procedure.
- Press buttons 0, 0 and 1 to select "Display group number 1" and press Q button to confirm input.
Indicated on display: (1 to 4 = display fields)
Read measuring value block 1 ->
1 2 3 4
NOTE: To switch to a different display group, proceed as follows:
- After C button is pressed, following appears.
Indicated on display:
Read measuring value block HELP
Enter display group number XXX
- Now desired display group number can be entered.