Operation CHARM: Car repair manuals for everyone.

Reading Measuring Value Blocks




Measuring Value Block, Reading

- V.A.G1551 Scan Tool with V.A.G1551/3 Adapter

Test requirements
- Coolant temperature must be at least 80 °C, See Display group 04, display field 3
- All electrical consumers like, for example, lights and rear window defogger must be switched off.
- If vehicle is equipped with an A/C system, it must be switched off.
- For vehicles with automatic transmission, selector lever must be in -P- or -N-.
- There must not be any DTCs stored in DTC memory, Check DTC memory.

Procedure

- Connect V.A.G 1551 scan tool (VAG1552). Start engine and select Engine Control Module (ECM) using address word 01. (Connecting scan tool and selecting ECM) [1][2][3]Connecting VAG 1551 Scan Tool

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -8- to select "Read measuring value block" function 08. Press -Q- button to confirm input.

Indicated on display


Read Measuring Value Block HELP
Input display group number XXX



- Select desired display group number.


NOTE: Display group number 1 is used as an example to indicate procedure.


- Press buttons -0-, -0- and -1- to select "Display group number 1". Press -Q- button to confirm input.

Indicated on display (1-4 = display fields)


Read Measuring Value Block 1 ->
1 2 3 4



NOTE: To switch to a different display group, proceed as follows:







- If specified values are obtained in all display fields, press -> button.

Indicated on display


Rapid data transfer HELP
Select function XX



- Press buttons -0- and -6- to select "End data transfer" function 06. Press -Q- button to confirm input.


NOTE: Measuring value blocks not described in this chapter are under development and production at the moment. Indicated values are not relevant for troubleshooting in service stations.