Oxygen Sensor Heater For O2 Sensors After (TWC), Checking



Oxygen sensor heater for oxygen sensors behind Three Way Catalytic Converter (TWC), checking


NOTE: When servicing terminals 3 and 4 in harness connector of oxygen sensors, use only goldplated terminals.


Recommended special tools and equipment
- VAG1526 multimeter or VAG1715 multimeter
- VAG1594 connector test kit
- Wiring diagram

Test requirements







- The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- and Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) -G131- must be OK.







- Fuses -1, 2, 3, 4 and 7- in protective housing (plenum chamber, left) must be OK.
- Battery voltage must be at least 11.5 Volts.
- All electrical consumers such as, for example, lights and rear window defroster must be switched off.
- Parking brake must be engaged or else daylight driving lights will be switched on.
- For vehicles with automatic transmission, selector lever must be in position -P-or -N-.
- If vehicle is equipped with an A/C system, it must be switched off.
- Ground (GND) connections between engine and chassis must be OK.

Test sequence







- Disconnect 4-pin harness connector to the respective oxygen sensor:
- Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-, bank 1 4-pin harness connector (black) -3-,
- Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) -G131-, bank 2 4-pin harness connector (brown) -4-.


NOTE:
- Bank 1 = Cylinder bank 1, in direction of travel, right
- Bank 2 = Cylinder bank 2, in direction of travel, left


Checking voltage supply and wiring to control module







- Connect multimeter to terminals 1 + 2 of connector to Engine Control Module (ECM) for voltage measurement.
- Start engine, and let run at idle.
Specified value: at least 7.0 V

If specified value is obtained:
- Switch ignition off.
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.
- Generate readiness code. Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is not obtained:







- Connect multimeter to terminal 1 of connector to Engine Control Module (ECM) + Ground (GND) for voltage measurement.
Specified value: at least 11.0 V
- Switch ignition off.

If specified value is not obtained:
- Check voltage supply at 4-pin connector terminal 1 according to wiring diagram.
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.
- Generate readiness code. Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is obtained:
- Check Ground (GND) activation of the respective oxygen sensor heater.
- Connect test box to control module wiring harness, connect test box for wiring test. Test Box, Connecting For Wiring Test







- Check wires between test box and 4-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Wire resistance: max. 1.5 Ohms







- Also check wires for short circuit to B+ and Ground (GND).
Specified value: infinity Ohms
- Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.
- Generate readiness code. Monitors, Trips, Drive Cycles and Readiness Codes

If no malfunctions are found in wires:
- Replace Motronic Engine Control Module (ECM) -J220-.