Wastegate Bypass Regulator Valve, Checking






Wastegate Bypass Regulator Valve, Checking

Special tools, testers and auxiliary items required

Multimeter.

Wiring diagram.

Test requirements

The Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248) fuses OK.

Battery voltage at least 12.5 volts.

All electrical consumers such as, lights and rear window defroster, switched off.

On vehicles with automatic transmission, selector lever in position "P" or "N".

A/C switched off.

Ground (GND) connections between engine/transmission/chassis OK.

Ignition switched off.

Test procedure

- Perform a preliminary check to verify the customers complaint. Refer to => [ General Diagnosis ] General Diagnosis.

Start diagnosis

- Disconnect the Wastegate Bypass Regulator Valve (N75) electrical harness connector.

Checking internal resistance

- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) - 1 - terminals 1 to 2 for resistance.





Specified value: 20 to 30 ohms (at approx. 20° C)

If the specification was not obtained:

- Replace the Wastegate Bypass Regulator Valve (N75).

If the specification is obtained:

Checking Voltage supply

- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) electrical harness connector terminal 1 to Ground (GND).









- Operate the starter briefly.

Specified value: battery voltage.

- Switch the ignition off.

If the specification was not obtained:

- Check the wiring for a short circuit to Battery positive (+) or an open circuit.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the wiring connection.

If no malfunction is found in the wiring:

If the manufacturers test box is being used, perform the following step.

- Install the test box. Refer to => [ 68-Pin Test Box Adapter, VAG1598/19, Installing ] Diesel Direct Fuel Injection ECM, Checking.

If the manufacturers test box is not being used, perform the following step.

- Remove the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248). Refer to => [ Diesel Direct Fuel Injection ECM, Replacing ] Diesel Direct Fuel Injection ECM, Checking.

- Using a multimeter, check the Wastegate Bypass Regulator Valve (N75) electrical harness connector terminal 2 to the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248) electrical harness connector T60 terminal 29 for an open circuit.









Specified value: 1.5 ohms max.

If the specification is not obtained:

- Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and if the voltage supply was OK:

- Replace the Diesel Direct Fuel Injection (DFI) Engine Control Module (ECM) (J248). Refer to => [ Diesel Direct Fuel Injection ECM, Replacing ] Diesel Direct Fuel Injection ECM, Checking.

Final procedures

After the repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Readiness Code.