Generator Overview
Generator Overview
When disconnecting and connecting the Battery, the procedure must be followed as described in the repair information. Refer to=> [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.
1 Collar Bolts
• 20 Nm
2 Ribbed Belt Tensioner
3 Collar Bolts
• 20 Nm
4 Accessories Bracket
• For Generator and A/C compressor.
• For the tightening sequence.
5 Collar Bolts
• 40 Nm
6 Collar Bolts
• 40 Nm
7 Hex Bolt With Washer and Threaded Piece
• 2 Nm
8 Generator Cover
9 Phillips Head Screws
• 2 Nm
10 Cap For The Carbon Brushes
11 Voltage Regulator (C1)
• Removal and installation, refer to => [ Voltage Regulator ] Service and Repair.
12 Generator
• Removal and installation refer to => [ Generator ] Generator.
• Checking, refer to=> [ Generator, Checking ] Testing and Inspection.
• B+ wire mount, refer to => [ B+ Wire Connection to Generator ] Procedures.
13 Ribbed Belt
• Checking, refer to=> [ Ribbed Belt, Checking ] Ribbed Belt, Checking.
• For removing and installing.
• For the ribbed belt routing.
No illustration
• B+ wire nut on the back of the generator: 15 Nm
• Wire holder nut on the back of the generator: 3.2 N
• Ribbed belt pulley without freewheel: 65 Nm
• Ribbed belt pulley with freewheel: 80 Nm
• Auxiliary component bracket, removing and installing.