Heated Oxygen Sensor G39 and Oxygen Sensor Regulation before Catalytic Converter, Checking
Heated Oxygen Sensor G39 and Oxygen Sensor Regulation before Catalytic Converter, Checking
• Use only gold-plated terminals when servicing terminals in the electrical harness connector of the Heated Oxygen Sensor (HO2S) (G39).
Special tools, testers and auxiliary items required
• Multimeter.
• Wiring diagram.
Test requirements
• The Heated Oxygen Sensor (HO2S) (G39) fuse OK.
• The Oxygen Sensor (O2S) Heater (Z19) before catalytic converter OK. Refer to=> [ Oxygen Sensor Heater Z19 for Heated Oxygen Sensor G39 in front of Catalytic Converter, Checking ] Oxygen Sensor Heater Z19 for Heated Oxygen Sensor G39 in front of Catalytic Converter, Checking.
• Battery voltage at least 12.5 volts.
• All electrical consumers such as, lights and rear window defroster, switched off.
• A/C switched off.
• Ground (GND) connections between engine/transmission/chassis OK.
• Exhaust system between catalytic converter and cylinder head properly sealed.
• Coolant Temperature at least 80° C.
Function test
- Perform a function test. Refer to => [ Test-ID 01 ($01): Oxygen Sensor
Monitor Bank 1 - Sensor 1 ] Diagnostic Mode 06 - Read Test Results for Specific Diagnostic Functions.
If the specified values are not obtained:
Checking primary voltage
- Disconnect the black Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 -.
- Using a multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector - 1 - terminals 1 to 5 for voltage.
Specified value: 0.400 to 0.500 Volts
- Switch the ignition off.
If the specified value was obtained:
- Replace the Heated Oxygen Sensor (HO2S) (G39).
If the specified value is obtained:
Checking wiring
If the manufacturers test box is being used. Perform the following step.
- Install the Test Box 105 Pin (VAG1598/42).
If the manufacturers test box is not being used. Perform the following step.
- Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module J623, Removing and Installing ] Engine Control Module J623, Removing and Installing.
- Using a Multimeter, check the Heated Oxygen Sensor (HO2S) (G39) electrical harness connector terminals to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T94 terminals for an open circuit.
Specified value: 1.5 ohms Max.
If the specification was not obtained:
- Check the wiring for a short circuit to each other, Battery (+), and Ground (GND).
- Check the electrical harness connector for damage, corrosion, lose or broken terminals.
- If necessary, repair the faulty wiring connection.
If no malfunction is found in the wiring:
- Replace the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module J623, Removing and Installing ] Engine Control Module J623, Removing and Installing.
Final procedures
After the repair work, the following work steps must be performed in the following sequence:
1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Mode 03 - Read DTC Memory.
2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Mode 04 - Erase DTC Memory.
3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.
End of diagnosis