Operation CHARM: Car repair manuals for everyone.

Secondary Air Injection Solenoid Valve Checking







Secondary Air Injection Solenoid Valve Checking

Special tools, testers and auxiliary items required

Multimeter.

Wiring diagram.

Test requirements

Fuse (SB38) OK.

The ignition switched off.

Voltage for the Secondary Air Injection (AIR) Solenoid Valve (N112) is supplied by the Power Supply Relay (terminal 30, B+) (J317).

Test procedure

- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check.

Start diagnosis

- Disconnect the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector.

Checking internal resistance

- Using a multimeter, check the resistance between terminals 1 and 2 of the Secondary Air Injection (AIR) Solenoid Valve (N112).

Specified value: 22,0 to 30,0 ohms.

If the specified value was Not obtained:

- Replace the Secondary Air Injection (AIR) Solenoid Valve (N112).

If the specified value was obtained:

Checking voltage supply

- Using a multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector terminal 1 to Ground for voltage.





- Operate the starter briefly.

Specified value: Battery voltage.

If the specified value was Not obtained:

- Check the wiring connection from the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector terminal 1 to the Power Supply Relay (terminal 30, B+) (J317) terminal 87 for an open circuit, high resistance, a short circuit to Battery positive (+) or to Ground.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the wiring connection.

If the specified value was obtained:

Check Ground activation

If the manufacturers test box is being used. Perform the following step.

- Install the test box.

If the manufacturers test box is not being used. Perform the following step.

- Remove the Engine Control Module (ECM) (J623). Refer to the Repair Information.

- Using a multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical connector terminal 2 to the Engine Control Module (ECM) (J623) electrical harness connector T121 terminal 47 for resistance.










Specified value: 1.5 ohms.

If the specification was Not obtained:

- Check the wiring for an open circuit, high resistance, a short circuit to Battery positive (+) or to Ground.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the wiring connection.

If the specification was obtained:

- Erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 09.

- Perform a road test to verify repair.

If the DTC does not return:

Generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.

If the DTC returns, no malfunction is found in the wiring and voltage supply was OK:

- Replace the Engine Control Module (ECM) (J623). Refer to the Repair Information.

- Assembly is performed in the reverse of the removal.

Final procedures

After repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Modes 01 - 09.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 09.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.