Generator Overview
Generator Overview
When disconnecting and connecting the Battery, the procedure must be followed as described in the repair information. Refer to=> [ Battery, Disconnecting and Connecting ] Battery, Disconnecting and Connecting.
1 Collar Bolts
• 23 Nm
2 Collar Bolts
• 23 Nm
3 Accessories Bracket
• For Generator and A/C compressor.
4 Collar Bolts
• 45 Nm
5 Cap
6 Hex Head Collar Nut
7 Phillips Head Screw
• 4.5 Nm
8 Nut
9 Washer
10 Phillips Head Screws
• 2 Nm
11 Phillips Head Screw
• 2 Nm
12 Voltage Regulator (C1)
• Removal and installing, refer to => [ Voltage Regulator ] Service and Repair.
13 Generator
• Removal and installation, refer to => [ Generator ] Generator.
• Checking, refer to=> [ Generator, Checking ] Testing and Inspection.
• B+ wire mount, refer to => [ B+ Wire Connection to Generator ] Procedures.
14 Ribbed Belt
• Checking, refer to=> [ Ribbed Belt, Checking ] Ribbed Belt, Checking.
• Removal and installation
• For the ribbed belt routing.
15 Ribbed Belt Tensioner
No Illustration
• B+ wire nut on the back of the generator: 15 Nm
• Wire holder nut on the back of the generator: 3.2 Nm
• Ribbed belt pulley without freewheel: 65 Nm
• Ribbed belt pulley with freewheel: 80 Nm
• Auxiliary component bracket, removing and installing.