Exhaust Gas Recirculation Valve, Checking
Exhaust Gas Recirculation Valve, Checking
Special tools, testers and auxiliary items required
• Hand vacuum pump (VAG1390)
Test Sequence
- Remove connection pipe between charge air pipe and motor for intake flap.
- Disconnect vacuum hose at EGR valve.
- Connect hand vacuum pump to the valve.
- Operate hand vacuum pump and observe diaphragm rod.
Diaphragm rod must move in direction of arrow.
- Disconnect hose of hand vacuum pump from EGR valve.
Diaphragm rod must move back in opposite direction of arrow into the output position.