Post Injection Metering Pump
Post Injection Metering Pump
Metering pumps are secured on the subframe and inject diesel fuel behind the catalytic converters. The goal is to increase the exhaust temperature in order to burn the particle filter.
- 1 -: Bank 2 Particle Filter Post-Injection Metering Pump (V337)
- 2 -: Bank 1 Particle Filter Post-Injection Metering Pump (V336)
Metering pumps, securing
• - A -: Bolts, tightening specifications 9 Nm
• - B -: To the cylinder bank 2 catalytic converter.
• - C -: From the fuel tank
• - D -: To the cylinder bank 1 catalytic converter.
Metering Pumps for Post-injection in Particle Filter
Metering Pumps, Connecting Line
The metering pump fuel line is secured directly behind the catalytic converter in order to utilize its exhaust temperature.