Operation CHARM: Car repair manuals for everyone.

Intake Manifold: Testing and Inspection






Intake Air Pre-Heating, Checking

Special tools, testers and auxiliary items required

Chilling Spray (commercially available)

Installed only on cold climate vehicles.

Regulator Flap, Checking

- Remove the upper air filter housing and filter element. Refer to => [ Air Filter Housing Overview ] Service and Repair.

- Check the position of the regulator flap - 1 -.






- Spray the thermal element - arrow - with chilling spray.

The regulator flap must close the warm air connection completely at 14 °C (57.2 °F) and above.

Below 0 °C (32 °F), the regulator flap must open the warm air connection completely.