B196E






B196E - Power Liftgate Close Direction Full Open Switch Performance






For a complete wiring diagram, refer to.

When Monitored: During the power liftgate close cycle.

Set Condition: The full open switch was detected as remaining closed after the liftgate closed 20% from start of the close operation. May be triggered by an intermittent full open switch failure.






Theory of Operation

The Full Open Switch indicates when the gate is a few degrees from full open position. The switch is closed when the liftgate is fully open and the switch is open when the liftgate is either fully closed and latched or between full open and closed. It can be checked by manually opening and closing the liftgate while monitoring the scan tool.

Test Step 1 - DTC Present

With the scan tool, record and erase DTCs.

Turn the ignition OFF, wait 10 seconds, then turn the ignition ON.

Operate the power liftgate several times if possible.

With the scan tool, read Active DTCs.

Does the scan tool display B196E - Power Liftgate Close Direction Full Open Switch Performance?

Yes

Go to Test Step 2

No

Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the liftgate several times and check for any binding or obstructions.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

Test Step 2 - Obstruction Or Sticking Switch

Examine the liftgate for proper fit and alignment, foreign material in the drive unit or anything that would cause an obstruction to proper operation of the full open switch.

With the scan tool under PLGM, read the full open switch state.

Manually operate the liftgate from the full open to mid position several times while monitoring the scan tool.

Does the switch status change smoothly as the liftgate is pulled down from the full open position?

Yes

Go to Test Step 3

No

Go to Test Step 4

Test Step 3 - Liftgate Full Open Switch Sense Circuit Intermittent Short to Ground


Never operate the Power Liftgate Drive Unit with the link rod removed as it could damage the Drive Unit.

Gain access to the power liftgate drive unit harness connector.

Gain access to the power liftgate module.

With the scan tool in inputs/outputs, read the full open switch state.

Ensure the link rod is connected at this time.

Manually open the liftgate to mid position.

While monitoring the scan tool, wiggle the wiring harness from the power liftgate module to the full open switch on the power liftgate drive unit assembly.

Did the switch status ever change?

Yes

Repair the liftgate full open switch sense circuit for an intermittent short to ground.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

No

Replace the power liftgate drive unit.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

Test Step 4 - Logic Ground Circuit Open






Turn the ignition OFF.

Disconnect the power liftgate module C2 harness connector.

Disconnect the power liftgate drive unit harness connector.

Measure the resistance of the sensor ground circuit between the power liftgate module C2 harness connector and the power liftgate drive unit connector.

Is the resistance less than 2.0 ohms?

Yes

Go to Test Step 5

No

Repair the sensor ground circuit for an open.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

Test Step 5 - Liftgate Full Open Switch Sense Circuit Short to Ground






Connect the power liftgate module C2 harness connector.

Turn the ignition ON.

Measure the voltage between liftgate full open switch sense circuit and the sensor ground in the power driver unit connector.

While measuring the voltage, wiggle the power liftgate module to check for an intermittent short.

Is the voltage constantly above 4.6 volts?

Yes

Replace the power liftgate drive unit.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

No

Go to Test Step 6

Test Step 6 - Liftgate Full Open Switch Sense Circuit Short to Ground






Turn the ignition OFF.

Disconnect the power liftgate module C1 harness connector.

Measure the resistance between ground and the liftgate full open switch sense circuit in the power liftgate drive unit connector.

Is the resistance less than 10k ohms?

Yes

Repair the liftgate full open switch sense circuit for a short to ground.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

No

Go to Test Step 7

Test Step 7 - Liftgate Full Open Switch Sense Circuit Short to Logic Ground






Measure the resistance between the liftgate full open switch sense circuit and the logic ground circuit in the power liftgate drive unit harness connector.

Is the resistance less than 10k ohms?

Yes

Repair the liftgate full open switch sense circuit for a short to the ground.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

No

Go to Test Step 8

Test Step 8 - Liftgate Full Open Switch Sense Circuit Open






Measure the resistance of the liftgate full open switch sense circuit between the PLG C1 connector and the drive unit connector.

Wiggle the wiring harness from the power liftgate module to the full open switch on the power liftgate drive unit assembly.

Is the resistance less than 5.0 ohms?

No

Repair the liftgate full open switch sense circuit for an open.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior

Yes

Replace the power liftgate module.

Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior