B19E0
B19E0 - Left Sliding Door Handle Switch Circuit - Stuck
For a complete wiring diagram, refer to.
• When Monitored: Whenever the left rear door module is awake.
• Set Condition: The left rear door module has detected the left door in/out handle switch sense circuit voltage is below 3.2 volts for over 30 seconds.
Test Step 1 - Check For DTCs
• With the scan tool, record DTCs and any power sliding door inhibitors.
• Erase the DTCs.
• Turn the ignition OFF, wait 10 seconds, then turn the ignition ON.
• Attempt to operate the left power sliding door from the door handle.
• With the scan tool, check for DTCs.
Does the scan tool display B19E0 - Left Sliding Door Handle Switch Circuit - Stuck?
Yes
• Go to Test Step 2
No
• Check the outside handle and the inside push button for an intermittent sticking condition.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior
Test Step 2 - Check the Left Door In/Out Handle For Sticking.
• Check the outside handle and then the inside handle for sticking.
Is there a sticking problem?
No
• Go to Test Step 3
Yes
• Repair the sticking handle if possible. If a cable is sticking, replace the latch assembly.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior
Test Step 3 - Check the Left Door In/Out Handle Switch Sense Circuit for a Short to Ground.
• Turn the ignition OFF.
• Disconnect the left rear door module C2 harness connector.
• Measure the resistance between ground and the left door in/out handle switch sense.
• Be careful not to spread the terminals in the connector.
Is the resistance less than 10k ohms?
No
• Go to Test Step 4
Yes
• Repair the left sliding door release handle circuit for a short to ground.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior
Test Step 4 - Check the Left Door In/Out Handle Switch Sense Circuit for a Short to the Left Power Sliding Door MUX Return Circuit.
• Measure the resistance between the left door in/out handle switch sense circuit and the left power sliding door MUX return circuit in the door module C2 connector.
• Be careful not to spread the terminals in the connector.
Is the resistance less than 10k ohms?
No
• Replace the left rear door latch assembly.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior
Yes
• Repair the left door in/out handle switch sense circuit for a short to the left power sliding door MUX return circuit.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior