Reduced Oil Pressure Switch
Reduced Oil Pressure Switch
Special tools, testers and auxiliary items required
• Socket 24 mm and Jointed Extension (T40175)
Removing
- Remove the Exhaust Gas Recirculation (EGR) cooler pump (V400). Refer to => [ Exhaust Gas Recirculation Cooler Pump ] Exhaust Gas Recirculation Cooler Pump.
- Loosen the hose clamp - 2 -, remove the coolant hose and move it to the side.
• Ignore - 1 and 3 -.
- Disconnect the connector - arrow - from the reduced oil pressure switch (F378).
- Remove the switch using (T40175).
Installing
Installation is performed in the reverse order of removal, noting the following:
• Replace the seal.