Diagnostic Mode 02 - Read Operating Conditions
Diagnostic Mode 02 - Read Operating Conditions
When an emissions-related fault (pending DTC, visible in mode 07) is first detected, operating conditions are stored. Mode 02 makes it possible to access this freeze frame data as soon as this fault is shown in mode 03. Each control module only shows freeze frame data for one fault via mode 02. Therefore, there are two priority levels. If there is a malfunction with higher priority, the freeze frame data is overwritten
Fault with higher priority: Misfire or fuel trim faults. Fault with normal priority: All other emissions-related faults
Procedure
- Connect the scan tool.
- Start the engine and run at idle.
• If the engine does not start, crank the engine using starter for at least 5 seconds, do not switch the ignition off afterward.
- Select "Diagnostic Mode 2: Obtain operating conditions.".
- From the following table, select the desired the "PID", e.g. "PID 05-Coolant temperature" that is to be monitored.
The current values of the component or system that is being monitored will be displayed on the scan tool screen.
- Switch the ignition off.