B18B5
B18B5 - Master Power Window Switch - Stuck
For a complete wiring diagram, refer to.
• When Monitored: At all times.
• Set Condition: Whenever the module detects a left front window signal from the master power window switch, for over 30 seconds, this code will set.
Test Step 1 - Test for an Intermittent Condition
• Turn the ignition ON.
• With the scan tool, record and erase DTCs.
• Operate the master power window switch UP and DOWN several times.
• Wait 30 seconds.
• With the scan tool, check for DTCs.
Does the scan tool display B18B5 - Master Power Window Switch - Stuck?
Yes
• Go to Test Step 2
No
• The conditions that caused this code to set are not present at this time. Operate the switch several more times. If the switch ever sticks, replace it.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior
Test Step 2 - Master Power Window Switch
• Anytime this code is active, the switch must be replaced.
• Replace the master power window switch.
• Perform the Body Verification Test. Refer to => Non-DTC Based Diagnostics. Body Interior