Fluid - M/T: Service and Repair
Transmission Fluid Level, Checking
Special tools, testers and auxiliary items required
• Triple Square Socket Driver (3357)
• Torque Wrench (5-50 Nm) (V.A.G 1331)
For the correct fluid, refer to the Parts Catalog.
- Remove the noise insulation.
- Remove the plug - arrow - for checking the fluid level.
The level is correct when the fluid comes up to the bottom edge of the hole.
- Add fluid, if necessary, until it reaches the lower edge of the hole.
- If already assembled, install the plug - arrow - with a new seal.
- Tighten the plug - arrow - to specification. Refer to => [ Different Versions of the Oil Fill and Drain Plugs ].
Different Versions of the Oil Fill and Drain Plugs
I - Oil fill or drain plug with a multi-point socket head - 45 Nm
II - Oil fill or drain plug with a hex socket head - 30 Nm
- Install the noise insulation.