Checking Ground Lead [GE3]
Checking Ground Lead
- Ignition on.
- Disconnect switch.
Connect a voltmeter between switch connector terminals 5 and 6.
Voltmeter should read approx. battery voltage.
If reading is OK:
- Try another switch.
If reading is incorrect:
- Check lead between switch connector terminal 5 and ground point 31/50 for open circuit as per HA2. Open Circuit [HA2]
- Now go to: Checking signal lead GE4. Checking Signal Lead [GE4]