LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2008 >> Pilot 4WD V6-3.5L >> Repair and Diagnosis >> Accessories and Optional Equipment >> Antitheft and Alarm Systems >> Keyless Entry >> Testing and Inspection >> Door Key Cylinder Switch Test

Door Key Cylinder Switch Test

Door Key Cylinder Switch Test

1. Remove the door panel.
2. Disconnect the 3P connector from the key cylinder switch.






3. Check for continuity between the terminals.
- There should be continuity between the No.2 and No.3 terminals when the door key cylinder switch is in the LOCK position (Except driver's door without security).
- There should be no continuity between the No.2 and No.3 terminals when the door key cylinder switch is in the neutral position (Except driver's door without security).
- There should be continuity between the No.1 and No.2 terminals when the door key cylinder switch is in the UNLOCK position.
- There should be no continuity between the No.1 and No.2 terminals when the door key cylinder switch is in the neutral position.

4. If the continuity is not as specified, replace the switch.

NOTE: Make sure the slot in the switch is properly aligned with the tab on the key cylinder.