XB123 - Check HFP Relay and Circuits
- Key "OFF".
- Variable Control Relay Module (VCRM) disconnected.
- Disconnect High Speed Fuel Pump (HFP) relay.
- Key "ON".
- Is fuel pump off?
Yes -- Key "OFF". Go to XB124 (to check HFP circuit). XB124 - Check HFP Circuit For Short to Ground
No -- Key "OFF". Service short to power in power-to-pump / Fuel Pump Monitor (FPM) circuit. Reconnect all components. Rerun quick test. Quick Test Appendix (Detailed Testing Instructions)