Removal and Replacement
INSTRUMENT CLUSTER REMOVAL/INSTALLATION
CAUTION:
- When replacing the instrument cluster, the configuration procedure must be performed before removing the instrument cluster. Replacing the instrument cluster without performing the configuration procedure will result in system malfunction.
1. Perform the instrument cluster configuration when replacing it. Programming and Relearning
2. Remove the battery cover. (See Removal and Replacement)
3. Disconnect the negative battery cable. (See Removal and Replacement)
4. Remove the lower panel. Lower Panel Removal/Installation
5. Remove the upper column cover. Service and Repair
6. Remove the meter hood. Meter Hood Removal/Installation
7. Remove in the order indicated in the table.
8. Install in the reverse order of removal.
9. When replacing the instrument cluster of vehicles with the immobilizer system, perform the following procedure:
- See Advanced Keyless Entry And Start System.
CAUTION:
- The removed instrument cluster should be placed with the display side up to prevent grease from leaking from the meters.
Instrument Cluster Removal Note
1. Rotate the instrument cluster in the direction of the arrow and remove the instrument cluster.
Clip B Removal Note
1. Rotate the clip B 90°, then remove the clip B from the instrument cluster.