LEMON Manuals: Even more car manuals for everyone
Home >> Mercury >> 1996 >> Sable V6-182 3.0L >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Pinpoint Tests >> DD - Injection Pressure (IP) Sensor >> Tables and Charts

Tables and Charts

IP Sensor Graph:






Voltage values were calculated for Reference Voltage (VREF) = 5.0 volts. These values may vary 15 percent due to sensor and VREF variations.

Normal operating range is from 0 to 150 psi and values may vary by +/-2.5%. The IP sensor operates within the range of 40°C to 125°C.