Inhibitor Switch Adjustment
1. Remove manual control linkage from manual shaft of A/T assembly.
2. Set manual shaft of A/T assembly in "N" position.
3. Loosen inhibitor switch fixing bolts.
4. Insert pin into adjustment holes in both inhibitor switch and manual shaft of A/T assembly. Be sure to insert as vertical as possible.
5. Reinstall any part removed.
6. Check continuity of inhibitor switch.
Inhibitor Switch Inspection