Diagnosis Procedure
INTERIOR ROOM LAMP CONTROL CIRCUIT
Description
Controls each interior room lamp (ground side) by PWM signal.
NOTE:
PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming).
INTERIOR ROOM LAMP CONTROL CIRCUIT
Diagnosis Procedure
Regarding Wiring Diagram information, Interior Room Lamp.
1.CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
CONSULT-III
1. Turn ignition switch OFF.
2. Select "INT LAMP" of BCM (INT LAMP) active test item.
3. While operating the test item, check voltage between BCM connector M17 terminal 19 and ground.
Is the inspection result normal?
YES - Interior room lamp control circuit is operating normally.
Fixed ON-GO TO 3
Fixed OFF-GO TO 2
2.CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
1. Disconnect BCM connector M17 and front room/map lamp assembly connector.
2. Check continuity between BCM connector M17 (A) terminal 19 and front room/map lamp assembly connector R50 (B) terminal 2.
Is the inspection result normal?
YES - Check interior room lamps for an open. If OK, replace BCM. Body Control System. If NG, replace interior room lamp. Service and Repair.
NO - Repair the harness or connectors.
3.CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector M17 and front room/map lamp assembly connector.
3. Check continuity between BCM connector M17 terminal 19 and ground.
Is the inspection result normal?
YES - Check interior room lamps for a short circuit. If OK, replace BCM. Body Control System. If NG, replace interior room lamp. Service and Repair.
NO - Repair the harness or connectors.