Diagnosis Procedure
TRUNK ROOM LAMP CIRCUIT
Description
Controls the trunk room lamp (ground side) to turn the trunk room lamp ON and OFF.
TRUNK ROOM LAMP CIRCUIT
Diagnosis Procedure
Regarding Wiring Diagram information, Interior Room Lamp Control System.
1.CHECK TRUNK ROOM LAMP OUTPUT
CONSULT-III
1. Turn ignition switch ON.
2. Select "LUGGAGE LAMP TEST" of BCM (INT LAMP) active test item.
3. While operating the test item, check voltage between BCM connector M20 terminal 110 and ground.
Is the inspection result normal?
YES - Trunk room lamp control circuit is operating normally.
Fixed ON-GO TO 3
Fixed OFF-GO TO 2
2.CHECK TRUNK ROOM LAMP OPEN CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector M20 and trunk room lamp connector.
3. Check continuity between BCM connector M20 (A) terminal 110 and trunk room lamp connector B36 (B) terminal 2.
Is the inspection result normal?
YES - Check trunk room lamp for an open. If OK, replace BCM. Body Control System. If NG, replace trunk room lamp. Service and Repair.
NO - Repair harness or connectors.
3.CHECK TRUNK ROOM LAMP SHORT CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM connector M20 and trunk room lamp connector.
3. Check continuity between BCM connector M20 terminal 110 and ground.
Is the inspection result normal?
YES - Check trunk room lamp for a short circuit. If OK, replace BCM. Body Control System. If NG, replace trunk room lamp. Service and Repair.
NO - Repair harnesses or connectors.