Roof Warning Lamp
ROOF WARNING LAMP
Component Function Check
1. CHECK ROOF WARNING LAMP FUNCTION
1.Start engine.
2.Operate soft top to fully open and fully close.
3.Make sure that roof warning lamp illuminates.
Is the inspection result normal?
YES- INSPECTION END
NO- Go to Malfunction Indicator Lamp.
Diagnosis Procedure
1. CHECK ROOF WARNING LAMP CIRCUIT-I
1.Turn ignition switch OFF.
2.Disconnect soft top control unit harness connector.
3.Turn ignition switch ON.
4.Check voltage between soft top control unit harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- GO TO 2.
2. CHECK ROOF WARNING LAMP CIRCUIT-II
1.Turn ignition switch OFF.
2.Disconnect combination meter harness connector.
3.Check continuity between soft top control unit harness connector and combination meter harness connector.
4.Also check harness for short to ground and short to power.
Is the inspection result normal?
YES- Replace combination meter. Removal And Installation Regular Grade.
NO- Repair open circuit, short to ground or short to power in harness or connectors.
3. REPLACE SOFT TOP CONTROL UNIT
Replace soft top control unit. Removal And Installation.
Is the inspection result normal?
YES- INSPECTION END
NO- GO TO 4.
4. CHECK INTERMITTENT INCIDENT
Intermittent Incident Regular Grade.
- INSPECTION END