Trunk Room Lamp Circuit
TRUNK ROOM LAMP CIRCUIT
Description
Controls the trunk room lamp (ground side) to turn the trunk room lamp ON and OFF.
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following is normal.
- Battery saver output/power supply
- Trunk room lamp bulb
Diagnosis Procedure
Regarding Wiring Diagram information, Interior Room Lamp Control System.
1. CHECK TRUNK ROOM LAMP OUTPUT
1.Turn ignition switch OFF.
2.Remove the trunk room bulb.
3.Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- GO TO 2.
Fixed ON-GO TO 3.
Fixed OFF-Replace BCM. Service and Repair.
2. CHECK TRUNK ROOM LAMP OPEN CIRCUIT
Check continuity between BCM harness connector and trunk room lamp harness connector.
Is the inspection result normal?
YES- Replace trunk room lamp.
NO- Repair or replace harnesses.
3. CHECK TRUNK ROOM LAMP SHORT CIRCUIT
1.Disconnect BCM harness connector.
2.Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES- Replace BCM. Service and Repair.
NO- Repair or replace harnesses.