Refrigerant Pressure Sensor
REFRIGERANT PRESSURE SENSOR
Component Function Check
1. CHECK REFRIGERANT PRESSURE SENSOR FUNCTION
1.Start engine and warm it up to normal operating temperature.
2.Turn A/C switch and blower fan switch ON.
3.Check the voltage between ECM harness connector terminals under the following conditions.
*1: Except for California
*2: For California
Is the inspection result normal?
YES- INSPECTION END
NO- Proceed to "Diagnosis Procedure" .
Diagnosis Procedure
1. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
1.Disconnect refrigerant pressure sensor harness connector.
2.Turn ignition switch ON.
3.Check the voltage between refrigerant pressure sensor harness connector and ground.
Is the inspection result normal?
YES- GO TO 3.
NO- GO TO 2.
2. CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ECM harness connector.
3.Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
*1: Except for California
*2: For California
Is the inspection result normal?
YES- Perform the trouble diagnosis for power supply circuit.
NO- Repair or replace error-detected parts.
3. CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect ECM harness connector.
3.Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
*1: Except for California
*2: For California
4.Also check harness for short to power.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace error-detected parts.
4. CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT
1.Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
*1: Except for California
*2: For California
2.Also check harness for short to ground and to power.
Is the inspection result normal?
YES- GO TO 5.
NO- Repair or replace error-detected parts.
5. CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
Is the inspection result normal?
YES- Replace refrigerant pressure sensor. Refer to "Removal and Installation" Automatic Air Conditioning (with automatic air conditioner) or "Removal and Installation" Manual Air Conditioning (with manual air conditioner).
NO- Repair or replace error-detected parts.