Manual Air Conditioning
REFRIGERANT PRESSURE SENSOR
Removal and Installation
REMOVAL
1.Discharge the refrigerant. Refer to "Recycle Refrigerant" Recycle Refrigerant.
2.Remove the front bumper fascia. Refer to "Removal and Installation" Removal And Installation.
3.Disconnect the harness connector from the refrigerant pressure sensor.
4.Remove the refrigerant pressure sensor.
CAUTION:
Cap or wrap the opening of the refrigerant pressure sensor with suitable material such as vinyl tape to avoid the entry of air.
INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Do not reuse O-ring.
- Apply A/C oil to the O-ring of the refrigerant pressure sensor for installation.
- After charging refrigerant, check for leaks. Refer to "Leak Test" Leak Test.