Home >> Pontiac >> 2001 >> Bonneville V6-3.8L SC VIN 1 >> Repair and Diagnosis >> Powertrain Management >> Computers and Control Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Scan Tool Data, Normal Values and Definitions >> Scan Tool Data Definitions - Powertrain Systems >> HO2S Sensor 1

HO2S Sensor 1

The scan tool range is 0-1132 mV. Represents the fuel control exhaust oxygen sensor output voltage. Should fluctuate constantly within a range between 10 mV (lean exhaust) and 1000 mV (rich exhaust) while operating in Closed Loop.