LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 1997 >> SW2 L4-1.9L DOHC VIN 7 >> Repair and Diagnosis >> Starting and Charging >> Testing and Inspection >> Component Tests and General Diagnostics >> Generator Output

Generator Output

Generator Output Chart:




Generator Output Chart

Generator Output Table:




Generator Output Table

This chart shows the generators dependency on the electrical demand (load), generator temperature, and engine.

IMPORTANT: When testing a generator, the load, temperature and rpm must be considered to obtain the most accurate conclusion. When using the ARBST or a carbon pile tester (carbon pile fully On), the load will be approximately maximum load.