Interior Lamp Control Circuit Check [with Power Door Locks]
Interior Lamp Control Circuit Check [with Power Door Locks]
Description
Controls the following interior room lamps (ground side) by PWM signal
- Front room/map lamp assembly (if equipped)
- Room lamp 2nd row
NOTE:
PWM signal control period is approximately 250 Hz (in the gradual brightening/dimming).
Component Function Check
CAUTION:
Before performing the diagnosis, check that the following is normal.
- Battery saver output/power supply
- Front room/map lamp bulbs (if equipped)
- Room lamp 2nd row bulb
1. CHECK INTERIOR ROOM LAMP CONTROL FUNCTION
WITH SDT
1 Switch the front room/map lamp assembly (if equipped) and room lamp 2nd row switches to DOOR.
2 Turn ignition switch ON.
3 Select "INT LAMP" of BCM (INT LAMP) active test item.
4 While operating the test item, check that each interior room lamp turns ON/OFF (gradual brightening/dimming).
Is the inspection result normal?
YES
Interior room lamp control circuit is normal.
NO
Refer to "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to [Interior Room Lamp: Wiring Diagram [with Power Door Lock System] Interior Room Lamp: Wiring Diagram [with Power Door Lock System] ].
1. CHECK INTERIOR ROOM LAMP CONTROL OUTPUT
WITH SDT
1 Turn ignition switch ON.
2 Select "INT LAMP" of BCM (INT LAMP) active test item.
3 While operating the test item, check voltage between BCM connector M20 terminal 63 and ground.
Is the inspection result normal?
YES
Interior room lamp control circuit is operating normally.
Fixed ON
GO TO 3
Fixed OFF
ERROR! Unknown action!GO TO 2
2. CHECK INTERIOR ROOM LAMP CONTROL OPEN CIRCUIT
1 Turn ignition switch OFF.
2 Disconnect BCM connector M20, room lamp 2nd row connector and front room/map lamp connector (if equipped).
3 Check continuity between BCM connector M20 (A) terminal 63 and interior room lamp connectors.
Is the inspection result normal?
YES
Check interior room lamp for an open. If OK, replace the BCM. Refer to [BCM: Removal and Installation] Removal and Replacement. If NG, replace the interior room lamp. Refer to [Interior Room Lamp: Removal and Installation] Service and Repair.
NO
Repair the harness or connectors.
3. CHECK INTERIOR ROOM LAMP CONTROL SHORT CIRCUIT
1 Turn ignition switch OFF.
2 Disconnect BCM connector M20, room lamp 2nd row connector and front room/map lamp connector (if equipped).
3 Check continuity between BCM connector M20 terminal 63 and ground.
Is the inspection result normal?
YES
Check interior room lamp for a short circuit. If OK, replace the BCM. Refer to [BCM: Removal and Installation] Removal and Replacement. If NG, replace the interior room lamp. Refer to [Interior Room Lamp: Removal and Installation] Service and Repair.
NO
Repair the harness or connectors.