Automatic Running Board System
EXTERIOR PANELS / TRIM: AUTOMATIC RUNNING BOARD SYSTEM: 41,42: Hall Effect Sensor LH Pulse
42 - Hall Effect Sensor RH Pulse
DESCRIPTION
When there is noise present in the side auto step motor hall pulse signal, the side auto step controller ECU assembly halts the operation of the automatic running board.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. CHECK HARNESS AND CONNECTOR (SIDE AUTO STEP MOTOR - SIDE AUTO STEP CONTROLLER ECU)
(a) Disconnect the O25*1 or N23*2 side auto step motor assembly connector.
* *1: for LH
* *2: for RH
(b) Disconnect the A41 side auto step controller ECU assembly connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
for LH
for RH
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE SIDE AUTO STEP MOTOR ASSEMBLY Removal