A Remote Control System does not Operate
- CHECK MALFUNCTION SYMPTOMS
- Check for obstructions.
- Check that there are no obstructions between the switch assembly and the infrared ray emitting portion of the television display assembly.
OK: No obstructions.
- Check that there are no obstructions between the switch assembly and the infrared ray emitting portion of the television display assembly.
NG: REMOVE OBSTRUCTIONS
OK: GO TO NEXT STEP.
- Check for obstructions.
- CHECK BATTERY (SWITCH ASSEMBLY)
- Check the battery.
- Check that the dry-cell battery used for the switch assembly is not dead.
OK: It is not dead.
- Check that the dry-cell battery used for the switch assembly is not dead.
NG: REPLACE DRY-CELL BATTERY
OK: GO TO NEXT STEP.
- Check the battery.
- CLEAN THE INFRARED RAY EMITTING PORTION
- Clean the infrared ray emitting portion.
- Clean the infrared ray emitting portion on the television display assembly.
- Check whether the same malfunction occurs.
OK: The function returns to normal.
OK: END
NG: GO TO NEXT STEP.
- REPLACE SWITCH ASSEMBLY
- Replace the switch assembly and check if it operates normally.
OK: Normal operation.
OK: END
NG: PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE
- Replace the switch assembly and check if it operates normally.