LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2000 >> C70 L5-2.3L Turbo VIN 53 B5234T3 >> Repair and Diagnosis >> Accessories and Optional Equipment >> Antitheft and Alarm Systems >> Testing and Inspection >> Scan Tool Testing and Procedures >> Activating Functions

Activating Functions






Activating functions

Activation routines
The following can be activated in the immobilizer.
Activation of:
- VGLA output
- Antenna signal
- Relay 1
- Relay 2
To activate functions, the functions listed prior to these must be "clicked through".


Continue - Activating the VGLA output

-------------------------------------------------

Activating the VGLA output





Activating the VGLA output

VGLA output




- Ignition on.
The VGLA output can only be activated if the key in the ignition is approved.
The voltage at the output the rises (approximately battery voltage) and remains high until activation is stopped by pressing the stop button.

Other information:
To connect the breakout box, see Connecting the breakout box, Immobilizer Connecting the Breakout Box.






Continue - Do you wish to activate multiple functions?

-------------------------------------------------

Do you wish to activate multiple functions?

Yes - Activating antenna signal

No - Exit procedure

-------------------------------------------------

Activating antenna signal





Activating antenna signal

Antenna signal




- Ignition on.
The control module transmits a frequency (125 kHz on #9 and #10) for 4 seconds. Cannot be interrupted.
The frequency can be measured using a suitable multimeter with a frequency meter.

Other information:
To connect the breakout box, see Connecting the breakout box, Immobilizer Connecting the Breakout Box.






Continue - Do you wish to activate multiple functions?

-------------------------------------------------

Do you wish to activate multiple functions?

Yes - Activating relay 1

No - Exit procedure

-------------------------------------------------

Activating relay 1





Activating relay 1

Relay 1




- Ignition on.
The relay clicks on and off at a frequency of 0.5 Hz for 4 seconds. Cannot be interrupted.






Continue - Do you wish to activate multiple functions?

-------------------------------------------------

Do you wish to activate multiple functions?

Yes - Activating relay 2

No - Exit procedure

-------------------------------------------------

Activating relay 2





Activating relay 2

Relay 2




- Ignition on.
The relay clicks on and off at a frequency of 0.5 Hz for 4 seconds. Cannot be interrupted.





-------------------------------------------------