Readiness Code Reading
Readiness Code, Checking (> m.y. 1997)
NOTE: Check the readiness code for m.y. 1998.
- Connect VAG1551 or VAG1552 Scan Tool (ST) and press buttons -0- and -1- to insert "Engine Electronics" address word 01 (ignition switched on). [1][2]Scan Tool Connecting and Initial Checks
Indicated on display
Rapid data transfer HELP
Select function XX
- Press buttons -0- and -8- to select "Read Measuring Value Block" function 08.
Indicated on display
Rapid data transfer Q
08- Read Measuring Value Block
- Press -Q- button to confirm input.
Indicated on display
Read Measuring Value Block Q
Input display group number XXX
- Press buttons -0-, -3- and -6- to input display group number 36 (036).
Indicated on display
Read Measuring Value Block Q
Input display group number 036
- Press -Q- button to confirm input.
Specified value in display field 1: all values should be "0". (if readiness code is set).
If the readiness code is not set:
- Generate readiness code. Readiness Code, Generating