Readiness Code Reading
Readiness Code, Reading
Work sequence
- Connect vehicle diagnostic, testing and information system VAS 5051 and select vehicle system "01 - Engine electronics" from list. Engine must be idling. Connecting VAS 5051 Scan Tool
Indicated on VAS 5051:
- From list -1- select diagnostic function "08 - Reading measured value block".
Indicated on VAS 5051:
1 Enter display group
- Use keypad -2- to enter "086" for "Display group number 086" and confirm by touching Q key.
Indicated on VAS 5051:
- Check display in zone -1-.
- Specification: 0 0 0 0 0 0 0 0
Display Group 086:
Note on display zone 1:
Of primary importance is display zone 1. This display shows which system has been checked by the self-diagnosis since the fault memory was last erased or a new control module installed. After erasing the fault memory, all values which can be checked are set to "1"; on successful completion of testing the values are set to "0".
NOTE: Readiness code is only generated if all positions in display zone 1 are set to "0".
If specification "0 0 0 0 0 0 0 0" is obtained in display zone 1:
- Touch <- key.
If reading does not match specification:
- Generate readiness code Readiness Code, Generating