Air Injection Pump: Service and Repair
Secondary Air Injection Pump
Removing
- Remove secondary air injection combi-valve. Refer to => [ Secondary Air Injection Combination Valves ] Service and Repair.
- Separate the electrical connector - 1 -.
- Remove nuts - arrows - and remove secondary air injection pump.
Installing
Installation is in reverse order of removal, note the following:
- Install secondary air injection combination valve. Refer to => [ Secondary Air Injection Combination Valves ] Service and Repair.
Tightening Specifications