Operation CHARM: Car repair manuals for everyone.

P0615


P0615 STARTER RELAY





Description
TCM prohibits cranking other than at "P" or "N" position.




DTC Logic

DTC DETECTION LOGIC

DTC DETECTION LOGIC:






DTC CONFIRMATION PROCEDURE

NOTE:
If "DTC CONFIRMATION PROCEDURE" has been previously performed, always turn ignition switch
OFF. Then wait at least 10 seconds before performing the next test.
1.CHECK DTC DETECTION
With CONSULT-III
1. Shift the selector lever in "P" or "N" position.
2. Turn ignition switch ON and wait for at least 2 seconds.
3. Perform "Self Diagnostic Results" in "TRANSMISSION".
Is "P0615" detected?
YES - Go to P0615.
NO - Check intermittent incident. Refer to Intermittent Incident.




Diagnosis Procedure
1.CHECK STARTER RELAY SIGNAL
1. Turn ignition switch ON.
2. Check voltage between IPDM E/R connector terminal and ground.





Is the inspection result normal?
YES - Check starter relay circuit. Refer to Electrical Diagrams.
NO - GO TO 2.
2. CHECK HARNESS BETWEEN A/T ASSEMBLY AND IPDM E/R (PART 1)
1. Turn ignition switch OFF.
2. Disconnect A/T assembly connector and IPDM E/R connector.
3. Check continuity between A/T assembly vehicle side harness connector terminal and IPDM E/R vehicle side harness connector terminal.





Is the inspection result normal?
YES - GO TO 3.
NO - Repair or replace damaged parts.
3.CHECK HARNESS BETWEEN A/T ASSEMBLY AND IPDM E/R (PART 2)
Check continuity between A/T assembly vehicle side harness connector terminal and ground.





Is the inspection result normal?
YES - GO TO 4.
NO - Repair or replace damaged parts.
4.DETECT MALFUNCTIONING ITEM (PART 1)
Check the following.
- Check terminals of A/T assembly connector and IPDM E/R connector for damage.
- Check connector for loose connection.
Is the inspection result normal?
YES - GO TO 5.
NO - Repair or replace damaged parts.
5.CHECK TERMINAL CORD ASSEMBLY
1. Remove control valve with TCM. Refer to Exploded View.
2. Disconnect TCM connector.
3. Check continuity between A/T assembly harness connector terminal and TCM connector terminal.





Is the inspection result normal?
YES - GO TO 6.
NO - Repair or replace damaged parts.
6.DETECT MALFUNCTIONING ITEM (PART 2)
Check the following.
- Check terminals of TCM connector and harness cladding for damage.
- Check connector for loose connection.
Is the inspection result normal?
YES - Replace the control valve with TCM. Refer to Exploded View
NO - Repair or replace damaged parts.