Operation CHARM: Car repair manuals for everyone.

P0452


P0452 EVAP CONTROL SYSTEM PRESSURE SENSOR





Component Description
The EVAP control system pressure sensor detects pressure in the purge line. The sensor output voltage to the
ECM increases as pressure increases.














On Board Diagnosis Logic

NOTE:
If DTC P0452 is displayed with DTC P0643, first perform the trouble diagnosis for DTC P0643. P0643 P0643 P0643.









DTC Confirmation Procedure

NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Always perform test at a temperature of 5�C (41�F) or more.

WITH CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Turn ignition switch ON.
4. Select "DATA MONITOR" mode with CONSULT-III.
5. Make sure that "FUEL T/TMP SE" is more than 0�C (32�F).
6. Start engine and wait at least 20 seconds.
7. Check 1st trip DTC.
8. If 1st trip DTC is detected, go to P0452.

WITH GST
1. Start engine and warm it up to normal operating temperature.





2. Check that voltage between ECM terminal 107 (Fuel tank temperature sensor signal) and ground is less than 4.2 V.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and wait at least 20 seconds.
5. Select Service $07 with GST.
If 1st trip DTC is detected, go to P0452.




Diagnosis Procedure
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Power Supply and Ground Circuit.





OK or NG
OK - GO TO 2.
NG - Repair or replace ground connections.
2.CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.





2. Check sensor harness connector for water.

Water should not exist.

OK or NG
OK - GO TO 3.
NG - Repair or replace harness connector.
3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ON.





2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-III or tester.

Voltage: Approximately 5V

OK or NG
OK - GO TO 5.
NG - GO TO 4.
4.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
5.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
67. 3. Check harness continuity between EVAP control system pressure sensor terminal 1 and ECM terminal Refer to Wiring Diagram.

Continuity should exist.

4. Also check harness for short to ground and short to power.
OK or NG
OK - GO TO 7.
NG - GO TO 6.
6.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
7.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
2. 1. Check harness continuity between ECM terminal 32 and EVAP control system pressure sensor terminal Refer to Wiring Diagram.

Continuity should exist.

2. Also check harness for short to ground and short to power.
OK or NG
OK - GO TO 9.
NG - GO TO 8.
8.DETECT MALFUNCTIONING PART
Check the following.
- Harness connectors C1, E41
- Harness connectors E5, F14
- Harness for open or short between EVAP control system pressure sensor and ECM
- Repair open circuit or short to ground or short to power in harness or connectors.
9.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
P0452.
OK or NG
OK - GO TO 10.
NG - Replace EVAP control system pressure sensor.
10.CHECK INTERMITTENT INCIDENT
How to Check Terminal and Intermittent Incident.
- INSPECTION END




Component Inspection

EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected from EVAP canister.
Always replace O-ring with a new one.
2. Install a vacuum pump to EVAP control system pressure sensor.





3. Turn ignition switch ON and check output voltage between ECM terminal 32 and ground under the following conditions.






CAUTION:
- Always calibrate the vacuum pump gauge when using it.
- Do not apply below -93.3 kPa (-700 mmHg, -27.56 inHg) or pressure over 101.3 kPa (760 mmHg, 29.92 inHg).
4. If NG, replace EVAP control system pressure sensor.