B1488
DTC B1488
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (Diagnostic System Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (Strategy Based Diagnosis) for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions (Diagnostic Procedure Instructions) provides an overview of each diagnostic category.
DTC Descriptor
DTC B1488
- Generator L-Terminal Circuit High
Diagnostic Fault Information
Circuit/System Description
The generator battery control module controls the generator through the generator turn on signal circuit. The signal is a 5-volt pulse width modulation (PWM) signal of 128 Hz with a duty cycle of 0-100 percent. Normal duty cycle is 0 percent when the engine is not running. If the generator turn on signal circuit is 65 percent or greater duty cycle, or shorted to voltage, then DTC B1488 will set.
Conditions for Running the DTC
* The ignition is ON.
* The engine is OFF.
* This diagnostic runs every 100 ms.
Conditions for Setting the DTC
The generator turn on signal circuit duty cycle is greater than 65 percent for 5 seconds.
Action Taken When the DTC Sets
* The charge indicator turns ON.
* The driver information center (DIC) displays the SERVICE CHARGE SYS message.
Conditions for Clearing the DTC
* The DTC will pass when the conditions for setting the DTC are no longer present.
* The charge indicator and DIC message will remain ON until the ignition is cycled after clearing the DTC.
Reference Information
Schematic Reference
Starting and Charging Schematics ([1][2]Electrical Diagrams)
Connector End View Reference
Component Connector End Views (Component Connector End Views)
Description and Operation
Charging System Description and Operation (Description and Operation)
Electrical Information Reference
* Circuit Testing (Circuit Testing)
* Connector Repairs (Connector Repairs)
* Testing for Intermittent Conditions and Poor Connections (Testing For Intermittent Conditions and Poor Connections)
* Wiring Repairs (Wiring Repairs)
Scan Tool Reference
Control Module References (Programming and Relearning) for scan tool information
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the generator.
2. Ignition ON, test for less than 1 volt between the generator turn on signal circuit terminal 1 X1 and ground.
• If greater than the specified range, test the generator turn on signal circuit for a short to voltage. If the circuit tests normal, replace the GBCM.
3. Engine Running, test for greater than 3 volts between the generator turn on signal circuit terminal 1 X1 and ground.
• If less than the specified range, test the generator turn on signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the GBCM.
4. If the circuit tests normal, replace the generator.
Repair Instructions
Perform the Diagnostic Repair Verification (Verification Tests) after completing the diagnostic procedure.
* Generator Replacement (Service and Repair)
* Control Module References (Programming and Relearning) for GBCM replacement, setup, and programming.