P0A7A-522
L110 HYBRID VEHICLE CONTROL: HYBRID CONTROL SYSTEM: P0A7A-522: Generator Inverter Performance
DTC P0A7A-522 - Generator Inverter Performance
DESCRIPTION
For a description of the inverter, P0A78-266.
If the inverter receives a generator gate shutdown signal from the MG ECU, it will turn all power transistors off which are activating the generator to forcibly stop generator operation. The MG ECU monitors the generator gate shutdown signal line and detects malfunctions.
HINT:
- If DTC P0A7A-522 is output, the hybrid system cannot be restarted until the DTC is cleared.
- If the malfunction is not reproduced, leave the vehicle for 1 minute with the shift lever in the N position in order to easily reproduce the malfunction.
MONITOR DESCRIPTION
The MG ECU monitors the current that flows in MG1. If current flows in MG1 while the vehicle is stationary with the power switch on (IG) or the shift lever in the N position, the MG ECU will detect a malfunction. The hybrid vehicle control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
TYPICAL ENABLING CONDITIONS
TYPICAL MALFUNCTION THRESHOLDS
COMPONENT OPERATING RANGE
INSPECTION PROCEDURE
CAUTION:
- Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
- After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting, check the voltage at the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
HINT: Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
PROCEDURE
1. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
(a) Check the connection of the low voltage connector of the inverter with converter assembly.
OK:
The connector is connected securely and there are no contact problems.
NG -- CONNECT SECURELY
OK -- REPLACE INVERTER WITH CONVERTER ASSEMBLY