B1412
HEATING / AIR CONDITIONING: AIR CONDITIONING SYSTEM: B1412/12: Ambient Temperature Sensor Circuit
B1412/12 - Ambient Temperature Sensor Circuit
DESCRIPTION
The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature which is used to control the air conditioner "AUTO" mode. This sensor is connected to the A/C amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the A/C amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The A/C amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
1. READ VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the engine switch on (IG).
(c) Turn the Techstream on.
(d) Select the item below in the Data List, and read the display on the Techstream.
Data List / Air Conditioner
OK:
The display is as specified in the normal condition column.
Result:
C -- REPLACE A/C AMPLIFIER Removal
B -- PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE Symptom Related Diagnostic Procedures
A -- Continue to next step.
2. INSPECT AMBIENT TEMPERATURE SENSOR
(a) Remove the ambient temperature sensor.
(b) Disconnect the ambient temperature sensor connector.
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NOTICE:
* Hold the sensor only by its connector. Touching the sensor may change the resistance value.
* When measuring, the sensor temperature must be the same as the ambient temperature.
HINT
As the temperature increases, the resistance decreases (see the graph).
NG -- REPLACE AMBIENT TEMPERATURE SENSOR Removal
OK -- Continue to next step.
3. CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - A/C AMPLIFIER)
(a) Disconnect the A/C amplifier connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
NG -- REPAIR OR REPLACE HARNESS OR CONNECTOR
OK -- REPLACE A/C AMPLIFIER Removal