Symptom Related Diagnostic Procedures
Security SystemINSPECTION
1. BASIC DIAGNOSTIC PROCEDURE
NOTE: If the horn sounds when setting the security to ON (monitoring condition) using the keyless transmitter, check the function setting of body integrated unit. As a cause, it is possible that the impact sensor present (ON) / not present (OFF) setting is set to ON in the customization function though there is no impact sensor.
2. CHECK SECURITY SYSTEM CONDITION MEMORY
1. Pull out the key from the ignition switch, or turn the ignition to OFF.
2. Close all the doors, trunk lid and rear gate.
3. Open the front hood.
4. Press the LOCK button of the keyless transmitter.
NOTE: Wait until the security indicator light blinks twice within 0.5 seconds at 2 second intervals.
If the 30 second monitoring lag has been set, wait for 30 seconds.
5. Disconnect the ground cable from battery.
6. Connect the battery ground terminal.
7. Check that the security indicator light blinks twice within 0.5 seconds at 2 second intervals. When it does not blink, replace the body integrated unit.
3. SECURITY SYSTEM ON/OFF SETTING
NOTE: It can be set by [[Security Alarm Setup]] in unit customizing using Subaru Select Monitor. For detailed procedures, refer to "PC application help for Subaru Select Monitor".
1. Close all doors, trunk lid and rear gate, and sit down on the driver seat. Press the UNLOCK button of the keyless transmitter.
2. Turn the ignition switch to ON.
3. Press the central door unlock switch and open the driver's door simultaneously. (Keep the central door unlock switch pressed down.)
4. When the condition in step 3) continues for 10 seconds, the system switches to a mode reverse to the current mode.
4. CHECK DOOR SWITCH
For operation procedure, refer to "CHECK DOOR SWITCH" of "Keyless Entry System". Testing and Inspection
5. CHECK SECURITY INDICATOR LIGHT CIRCUIT
For operation procedures, refer to "CHECK SECURITY INDICATOR LIGHT CIRCUIT" of "IMMOBILIZER (DIAGNOSTICS)". Diagnostics Chart For Security Indicator Light
6. CHECK HORN
7. CHECK HAZARD LIGHT OPERATION
For operation procedure, refer to "CHECK HAZARD LIGHT OPERATION" of "Keyless Entry System". Testing and Inspection
8. CHECK IGNITION SWITCH CIRCUIT