Transmission Position Sensor/Switch: Adjustments
Multi-Function Transmission Range Switch Adjusting
Special tools, testers and auxiliary items required
• Setting gauge (T10173)
- Place the selector lever in the "N" position.
- Do not kink the selector lever cable.
Adjustment Prerequisites
• Selector lever cable is removed from the lever/shift rod
• Shift rod is in the "N" position
• Multi-Function transmission range switch (F125) bolts are loosened
• Lever/shift rod is removed
- Install the (T10173) onto the shift rod - 2 - and turn the multi-function switch - 1 - until the (T10173) engages on the tab of the connector at the multi-function switch.
- Secure the (T10173) to the shift rod - 2 - using bolt - 3 -.
- Tighten the bolts - arrows - to 6 Nm.
- Remove the (T10173).
- Further installation is performed in the reverse sequence, refer to => [ Installing ] Service and Repair.